Media 000508988: Quadrate
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000508988: Quadrate
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000508988
Media type
Mesh
Object element or part
Quadrate
Object represented
Object taxonomy
Perdix perdix
Object organization
Side
Right
Orientation
--
Short description
Complete right quadrate
Full description
--
Creator
Kuo, Pei-Chen
Date created
March 29, 2023
Date uploaded
March 29, 2023
FILE OBJECT DETAILS Field Definitions
File name
Perdix_cinerea_UMZC_406_Quadrate.ply
File format(s)
PLY
File size
3.97 MB
Points
59774
Polygons
119544
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.166, 7.838, 6.055
Centroid coordinates
24.851, 48.995, 52.674
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
umzc:vertebrates:406
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000519491: Skull [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Pei-Chen Kuo
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000519491: Skull [CTImageSeries] [CT]
was processed
to create
derived
Media 000508988: Quadrate [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Kuo, Pei-Chen
Event date
March 29, 2023
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000508988: Quadrate [Mesh] [CT] (this media)