Media 000510260: Whole Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000510260
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Suncus etruscus
Side
--
Orientation
--
Short description
adult, whole body in alcohol
Full description
--
Creator
--
Date created
--
Date uploaded
March 31, 2023

FILE OBJECT DETAILS Field Definitions

File name
Suncus_etruscus-ad-body-SMNS49066_Rec.zip
File format(s)
ZIP archive, TIFF
File size
4.28 GB
Image width
1532
Image height
1444
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
13.391677
Y pixel spacing
13.391677
Z pixel spacing
13.391677
Pixel spacing units
Um
Slice thickness
--
Number of images in set
2,645

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker Skyscan 1272, Staatliches Museum für Naturkunde Stuttgart (Staatliches Museum für Naturkunde Stuttgart)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smns:z-mam:49066 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Staatliches Museum für Naturkunde Stuttgart (Staatliches Museum für Naturkunde Stuttgart)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000510260: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
NRecon 1.7.1.6
Description

Media produced by this event on MorphoSource

Media 000510260: Whole Body [CTImageSeries] [CT] (this media)