Media 000510266: Skull
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000510266
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Cricosaurus araucanensis
Side
--
Orientation
--
Short description
Cricosaurus araucanensis - skull STL
Full description
Cricosaurus araucanensis (MLP 72-IV-7-1) - skull STL
Creator
--
Date created
--
Date uploaded
March 31, 2023

FILE OBJECT DETAILS Field Definitions

File name
Cricosaurus_araucanenss_skull_STL.stl
File format(s)
STL
File size
17.8 MB
Points
187144
Polygons
373776
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
209.505, 154.323, 470.000
Centroid coordinates
111.806, 126.603, 165.355
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Philips Brilliance 6, Unidad Tomografía Computada (Hospital Interzonal de Agudos de la Matanza “Dr. Diego Pairoissien”)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MLP:72-IV-7-1 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Unidad Tomografía Computada (Hospital Interzonal de Agudos de la Matanza “Dr. Diego Pairoissien”)
Creator
--
Event date
--
Software
--
Description
X Pixel Spacing: 0.448 mm, Y Pixel Spacing: 0.448 mm, Z Pixel Spacing: 0.448 mm
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000510266: Skull [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000510266: Skull [Mesh] [CT] (this media)