Media 000512867: Articular And Prearticular
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000512867
Media type
Volumetric Image Series
Object element or part
articular and prearticular
Object represented
Object taxonomy
Masiakasaurus knopfleri
Side
Right
Orientation
--
Short description
right articular and prearticular
Full description
right articular and prearticular
Creator
Groenke, Joseph
Date created
February 10, 2023
Date uploaded
April 06, 2023

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, DICOM
File size
257 MB
Image width
450
Image height
265
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.049300
Y pixel spacing
0.049300
Z pixel spacing
0.049300
Pixel spacing units
Mm
Slice thickness
0.0493
Number of images in set
1,476

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore CT 120 in vivo, Ohio University MicroCT Facility (Ohio University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
O'Connor, Patrick
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR_1123642; NSF EAR_9418816; NSF EAR_1525915; Ohio University Heritage College of Osteopathic Medicine; NSF DBI_2242717
Publisher
O'Connor, Patrick; Mahajanga Basin Project
Cite as
Patrick M. O'Connor and colleagues provided access to these data originally published in SVP Memoir 8 (2007, Vol. 27, Suppl. 2) with data collection and processing funded by the US NSF EAR_9418816, NSF EAR_1123642, NSF EAR_1525915, NSF DBI_2242717 and Ohio University Heritage College of Osteopathic Medicine. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ua:9166 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Witmer, Larry; Ridgley, Ryan
Event date
February 10, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
20 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
120
Power
--
Amperage
32
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000512867: Articular And Prearticular [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Groenke, Joseph
Event date
February 10, 2023
Software
Avizo
Description
cropping and output as dicoms to replace field number(s) with museum accession number
Description attachment
None

Media produced by this event on MorphoSource

Media 000512867: Articular And Prearticular [CTImageSeries] [CT] (this media)