Media 000516089: Cranium
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000516089
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Chelus fimbriatus
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
April 18, 2023
Date uploaded
April 18, 2023

FILE OBJECT DETAILS Field Definitions

File name
Chelus_fimbriatus_SMF99270_Cranium.ply
File format(s)
PLY
File size
298 MB
Points
7090239
Polygons
14220636
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.591, 21.301, 7.765
Centroid coordinates
9.861, 23.780, 6.413
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon HT X 320, 3D Imaging Lab - 3DImg (Eberhard Karls Universität Tübingen/Geowissenschaften Fachbereich)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
SNSF Ambizione PZ00P2_202019/1
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smf:99270 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
3D Imaging Lab - 3DImg (Eberhard Karls Universität Tübingen/Geowissenschaften Fachbereich)
Creator
Christina Kyriakouli; Gabriel Ferreira
Event date
July 22, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
125 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
180 kV
Power
--
Amperage
80 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000516077: Cranium And Mandible [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000516077: Cranium And Mandible [CTImageSeries] [CT] was processed to create derived Media 000516089: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Serjoscha Evers
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000516089: Cranium [Mesh] [CT] (this media)