Media 000523055: Whole Body
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000523055
Media type
Mesh
Object element or part
Whole body
Object represented
Object taxonomy
Paikwaophis kruki
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Philippe J. R. Kok
Date created
September 23, 2022
Date uploaded
May 12, 2023

FILE OBJECT DETAILS Field Definitions

File name
NHMUK2023.3183_Paikwaophis_kruki_body_mesh.stl
File format(s)
STL
File size
104 MB
Points
1055487
Polygons
2156785
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
34.517, 31.500, 36.438
Centroid coordinates
-31.963, 1.667, 145.465
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object RBINS:2734 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Philippe J. R. Kok
Event date
September 23, 2022
Software
--
Description
Full body
Description attachment
None
Reference attachment
None
Exposure time
500 s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
120 kV
Power
12.4799 W
Amperage
104 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000523055: Whole Body [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Philippe J. R. Kok
Event date
September 23, 2022
Software
VGStudio MAX version 2.1
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000523055: Whole Body [Mesh] [CT] (this media)