Media 000537926: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000537926
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Phyllodactylus baurii gorii
Object organization
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Record created by batch submission.
Creator
Edward Stanley
Date created
--
Date uploaded
July 07, 2023

FILE OBJECT DETAILS Field Definitions

File name
CAS-herp-09413-head.zip
File format(s)
ZIP archive, TIFF
File size
622 MB
Image width
1251
Image height
586
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.014094
Y pixel spacing
0.014094
Z pixel spacing
0.014094
Pixel spacing units
Mm
Slice thickness
0.01409401
Number of images in set
1,969

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-2001435; NSF DBI-1701714
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:9413 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
200.098
Flux normalization
no
Pixel spacing calibration
--
Shading correction
no
Frame averaging
3
Projections
2000
Voltage
80
Power
0.0144
Amperage
180
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2024
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
56.571625
Source detector distance
802.77534791
Target material
tungston
Rotation number
--
Phase contrast
no
Optical magnification
no
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000537926: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
DatosX|R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000537926: Head [CTImageSeries] [CT] (this media)