Media 000542229: Nasal Airway
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000542229: Nasal Airway
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000542229
Media type
Mesh
Object element or part
Nasal airway
Object represented
Object taxonomy
Meleagris gallopavo
Object organization
Side
NotApplicable
Orientation
--
Short description
Nasal airway of Meleagris gallopavo
Full description
Nasal airway of Meleagris gallopavo OUVC 10599, male
Creator
Jason Bourke
Date created
July 17, 2023
Date uploaded
July 17, 2023
FILE OBJECT DETAILS Field Definitions
File name
STL-OUVC-10599-Airway.stl
File format(s)
STL
File size
194 MB
Points
520503
Polygons
1041544
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1.627, 1.852, 5.160
Centroid coordinates
4.141, 3.394, 4.265
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore CT 120 in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ouvc:10599
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ryan Ridgely
Event date
--
Software
--
Description
Head of a subadult, male turkey
Description attachment
None
Reference attachment
None
Filter
7
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1200
Voltage
80
Power
0.036
Amperage
450
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000536240: Wet Specimen, Head. [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000536240: Wet Specimen, Head. [CTImageSeries] [CT]
was processed
to create
derived
Media 000542229: Nasal Airway [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Jason
Event date
--
Software
Avizo
Description
Airway of Meleagris gallopavo, OUVC 10599, male.
Description attachment
None
Media produced by this event on MorphoSource
Media 000542229: Nasal Airway [Mesh] [CT] (this media)