Media 000553394: Lower Second Molar (Cast)
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000553394
Media type
Mesh
Object element or part
lower second molar (cast)
Object represented
Object taxonomy
Hapalemur griseus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
August 26, 2023
Date uploaded
August 26, 2023

FILE OBJECT DETAILS Field Definitions

File name
Hap_gr_USNM063355_m2_orient_smooth_fix_GM_asc_MD_flip_10k.ply
File format(s)
PLY
File size
312 KB
Points
5084
Polygons
9998
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.642, 4.736, 2.773
Centroid coordinates
11.486, 32.543, 72.136
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
2
Number of processing events
3 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:mammals:063355 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000000600: Second Mandibular Molar [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Processing Details Field Definitions

Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 4: IMAGE PROCESSING

Derived Media 000000598: Second Mandibular Molar [Mesh] [Etc] was processed with 1 activity to create derived Media 000553394: Lower Second Molar (Cast) [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Smoothing/Noise Reduction

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000553394: Lower Second Molar (Cast) [Mesh] [CT] (this media)