Media 000571414: Whole Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000571414
Media type
Volumetric Image Series
Object element or part
Whole Body
Object represented
Object taxonomy
Genyochromis mento
Side
NotApplicable
Orientation
--
Short description
Genyochromis mento
Full description
Individual A
Creator
Benson, Roger
Date created
March 08, 2022
Date uploaded
October 14, 2023

FILE OBJECT DETAILS Field Definitions

File name
Genyochromis_mento_NHMUK_1965_10_26_24_29_8bit_a.zip
File format(s)
ZIP archive, TIFF
File size
2.65 GB
Image width
974
Image height
1376
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.027004
Y pixel spacing
0.027004
Z pixel spacing
0.027004
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
4,216

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NHMUK:ZOO:1965.10.26.24-29 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Benson, Roger
Event date
March 08, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
250
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1801
Voltage
60
Power
16.62
Amperage
277
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000571414: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000571414: Whole Body [CTImageSeries] [CT] (this media)