Media 000573207: Whole Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000573207
Media type
Volumetric Image Series
Object element or part
Whole Body
Object represented
Object taxonomy
Rhamphochromis sp. 'kingiri dwarf'
Side
NotApplicable
Orientation
--
Short description
Rhamphochromis sp. 'kingiri dwarf'
Full description
Individual B. Sex unknown.
Creator
Benson, Roger
Date created
November 22, 2022
Date uploaded
October 25, 2023

FILE OBJECT DETAILS Field Definitions

File name
Rhamphochromis_sp_kingiri_dwarf_UniBri_NA_8bit_b.zip
File format(s)
ZIP archive, TIFF
File size
518 MB
Image width
471
Image height
764
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.030284
Y pixel spacing
0.030284
Z pixel spacing
0.030284
Pixel spacing units
Millimeters
Slice thickness
--
Number of images in set
2,765

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object L-MJG:n/a was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Benson, Roger
Event date
November 22, 2022
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
500
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1201
Voltage
80
Power
28
Amperage
350
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000573207: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000573207: Whole Body [CTImageSeries] [CT] (this media)