Media 000579200: Dice Ct Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

GENERAL DETAILS Field Definitions

Media ID
000579200
Media type
Volumetric Image Series
Object element or part
diceCT head
Object represented
Object taxonomy
Aneides lugubris
Side
--
Orientation
--
Short description
stained with 1.25% buffered Lugol's iodine
Full description
--
Creator
Jaimi Gray
Date created
May 24, 2023
Date uploaded
November 06, 2023

FILE OBJECT DETAILS Field Definitions

File name
MVZ-herp-158407-diceCT-head.zip
File format(s)
ZIP archive, TIFF
File size
1.6 GB
Image width
922
Image height
1654
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.017900
Y pixel spacing
0.017900
Z pixel spacing
0.017900
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,847

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MVZ:Herp:MVZ:Herp:158407 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Event date
May 24, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
200 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
2200
Voltage
90 kV
Power
--
Amperage
200 uA
Surrounding material
--
X-ray tube type
Tungsten
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000579200: Dice Ct Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Jaimi Gray
Event date
May 24, 2023
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000579200: Dice Ct Head [CTImageSeries] [CT] (this media)