Media 000581809: Element Unspecified
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

Media preview currently unavailable. Please check back later.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000581809
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Isopoda indet.
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Sarah R. Losso
Date created
November 09, 2023
Date uploaded
November 14, 2023

FILE OBJECT DETAILS Field Definitions

File name
MeshMCZ90105_seg_clean.ply
File format(s)
PLY
File size
462 MB
Points
12713192
Polygons
25527247
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.330, 4.530, 4.350
Centroid coordinates
2.269, 2.447, 2.253
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mcz:iz:90105 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
--
Event date
May 05, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
750
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
4
Projections
--
Voltage
70
Power
--
Amperage
114
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000581806: Element Unspecified [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Sarah R. Losso
Event date
November 09, 2023
Software
Dragonfly
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000581806: Element Unspecified [CTImageSeries] [CT] was processed to create derived Media 000581809: Element Unspecified [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Sarah R. Losso
Event date
November 09, 2023
Software
Dragonfly
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000581809: Element Unspecified [Mesh] [CT] (this media)