Media 000590223: Head
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000590223
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Atretochoana eiselti
Side
--
Orientation
--
Short description
--
Full description
DICECT scan reconstructed at 2X
Creator
Edward Stanley
Date created
April 30, 2019
Date uploaded
December 08, 2023

FILE OBJECT DETAILS Field Definitions

File name
UF-herp-185560-DICECT-head-2X.zip
File format(s)
ZIP archive, TIFF
File size
3.04 GB
Image width
1647
Image height
968
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.012385
Y pixel spacing
0.012385
Z pixel spacing
0.012385
Pixel spacing units
Mm
Slice thickness
0.01238538976758718
Number of images in set
2,310

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:185560 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
April 30, 2019
Software
Datos|X|R
Description
2X reconstruction of DICECT Atretochoana
Description attachment
None
Reference attachment
None
Exposure time
0.333096
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2200
Voltage
125
Power
25
Amperage
200
Surrounding material
air
X-ray tube type
240kV
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2014
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
99.75325000
Source detector distance
805.41067323
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000590223: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
Datos X R
Description
Reconstructed 2X
Description attachment
None

Media produced by this event on MorphoSource

Media 000590223: Head [CTImageSeries] [CT] (this media)