Media 000590257: Endocast
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000590257
Media type
Mesh
Object element or part
endocast
Object represented
Object taxonomy
Archaeopteryx lithographica
Side
Left
Orientation
--
Short description
--
Full description
The left side of the endocast was reflected to make complete specimen.
Creator
Amy Balanoff
Date created
January 01, 2013
Date uploaded
December 08, 2023

FILE OBJECT DETAILS Field Definitions

File name
Archaeopteryx.stl
File format(s)
STL
File size
40.4 MB
Points
422264
Polygons
846246
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
13.299, 13.323, 26.549
Centroid coordinates
1.726, 0.762, -2.041
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
The Trustees of the Natural History Museum, London
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NHMUK:PAL:PV OR 37001 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000590257: Endocast [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Amy Balanoff
Event date
January 01, 2013
Software
--
Description
The endocast was constructed from the left side of the specimen and reflected.
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
VGStudio MAX
Description

Processing Activity 2: Transform: Reflection

Software
VGStudio MAX
Description

Media produced by this event on MorphoSource

Media 000590257: Endocast [Mesh] [CT] (this media)