Media 000590278: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000590278: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000590278
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Odobenus rosmarus
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1343
Rowe:
odobe: Scans of a baby walrus skull of Odobenus rosmarus divergens (MVZ 63308; Sevoonga, St. Lawrence Island, Alaska; coll. 1931, female) for Tim Rowe and Digimorph of the University of Texas at Austin. Specimen scanned by Philip Watson 4 November 2005.
16bit: 1024x1024 16-bit TIFF images. P250D, 420 kV, 1.8 mA, no filter, air wedge, 160% offset, 32 ms integration time, slice thickness (= 0.25 mm), S.O.D. 641 mm, 1000 views, 1 ray averaged per view, 1 sample per view, inter-slice spacing (= 0.2 mm), field of reconstruction 208 mm (maximum field of view 210.154 mm), reconstruction offset 9300, scanner scale 7200, reconstruction scale 2200. Ring removal processing done by Alison Mote based on correction of raw sinogram data using IDL routine “RK_SinoRingProcSimul” with default parameters. Reconstructed with an angle of 170 degrees. Images were flipped horizontally in Photoshop and then renumbered in reverse order. Total slices = 620.
Creator
Philip Watson
Date created
November 04, 2005
Date uploaded
December 08, 2023
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
633 MB
Image width
712
Image height
1005
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.200000
Y pixel spacing
0.200000
Z pixel spacing
0.200000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
620
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
IIS-0208675; DBI-1902242
Publisher
oUTCT PEN
Cite as
These data made available by Tim Rowe, acquired for DigiMorph.org under IIS-0208675, oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mvz:mammal specimens:63308
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000590278: Skull [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000590278: Skull [CTImageSeries] [CT] (this media)