Media 000591609: Dice Ct Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

TAGS

GENERAL DETAILS Field Definitions

Media ID
000591609
Media type
Volumetric Image Series
Object element or part
diceCT whole body
Object taxonomy
Pseudoxenodon macrops
Side
--
Orientation
--
Short description
stained with 1.25% buffered Lugol's iodine
Full description
--
Creator
Jaimi Gray
Date created
April 12, 2022
Date uploaded
December 13, 2023

FILE OBJECT DETAILS Field Definitions

File name
FMNH-R-204497-diceCT-body.zip
File format(s)
ZIP archive, TIFF
File size
963 MB
Image width
680
Image height
1818
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.078453
Y pixel spacing
0.078453
Z pixel spacing
0.078453
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,527

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Amphibians and Reptiles:204497 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Event date
April 12, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
333 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
2200
Voltage
170 kV
Power
--
Amperage
200 uA
Surrounding material
--
X-ray tube type
Tungsten
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000591609: Dice Ct Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Jaimi Gray
Event date
April 12, 2022
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000591609: Dice Ct Whole Body [CTImageSeries] [CT] (this media)