Media 000593883: Whole Body Dicect
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000593883: Whole Body Dicect
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000593883
Media type
Volumetric Image Series
Object element or part
Whole body DICECT
Object represented
Object taxonomy
Barbourula kalimantanensis
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
DICECT scan of Barbourula kalimantanensis ZRC:12528
Creator
Edward Stanley
Date created
--
Date uploaded
January 03, 2024
FILE OBJECT DETAILS Field Definitions
File name
ZRC12528.zip
File format(s)
ZIP archive, TIFF
File size
1.6 GB
Image width
1739
Image height
639
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.016244
Y pixel spacing
0.016244
Z pixel spacing
0.016244
Pixel spacing units
Mm
Slice thickness
0.01624368
Number of images in set
3,231
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zrc:fis:12528
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
Phoneix Datos|X A
Description
DICECT scan of LKCNHM:ZRC:12528
Description attachment
None
Reference attachment
None
Exposure time
0.250097
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2200
Voltage
100
Power
16
Amperage
160
Surrounding material
air
X-ray tube type
240kV D
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2014
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000593883: Whole Body Dicect [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
DatosX|R
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000593883: Whole Body Dicect [CTImageSeries] [CT] (this media)