Media 000594318: Dice Ct Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000594318: Dice Ct Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000594318
Media type
Volumetric Image Series
Object element or part
diceCT whole body
Object represented
Object taxonomy
Pseudomugil signifer
Object organization
Side
--
Orientation
--
Short description
stained with 1.25% buffered Lugol's iodine
Full description
--
Creator
Jaimi Gray
Date created
August 23, 2022
Date uploaded
January 05, 2024
FILE OBJECT DETAILS Field Definitions
File name
KU-29884-diceCT.zip
File format(s)
ZIP archive, TIFF
File size
383 MB
Image width
621
Image height
416
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.010067
Y pixel spacing
0.010067
Z pixel spacing
0.010067
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,597
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas Biodiversity Institute
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
KU:KUI:29884
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Event date
August 23, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
Al 0.3 mm
Exposure time
250 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1680
Voltage
60kV
Power
--
Amperage
170 uA
Surrounding material
--
X-ray tube type
Tungsten
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000594318: Dice Ct Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Jaimi Gray
Event date
August 23, 2022
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000594318: Dice Ct Whole Body [CTImageSeries] [CT] (this media)