Media 000603811: Caudal Vertebra
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000603811: Caudal Vertebra
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000603811
Media type
Mesh
Object element or part
Caudal Vertebra
Object represented
Object taxonomy
Squamata indet.
Object organization
Side
NotApplicable
Orientation
--
Short description
Caudal Vertebra
Full description
--
Creator
Andrej Čerňanský
Date created
March 20, 2022
Date uploaded
February 10, 2024
FILE OBJECT DETAILS Field Definitions
File name
IRSNB_R_502_Squamata_indet_vertebra.ply
File format(s)
PLY
File size
280 MB
Points
3778541
Polygons
7563200
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.509, 8.944, 15.167
Centroid coordinates
5.105, 22.627, 9.079
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Phoenix V|tome|x L 240, Earth Science Institute Laboratory of Computed Tomography (Slovak Academy of Sciences)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Scientific Grant Agency of the Ministry of Education of Slovak Republic and Slovak Academy of Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
RBINS-Scientific Heritage:R:502
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Earth Science Institute Laboratory of Computed Tomography (Slovak Academy of Sciences)
Creator
Andrej Čerňanský
Event date
March 15, 2022
Software
VG Studio Max 3.1
Description
Caudal Vertebra
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
80 V
Power
--
Amperage
200 A
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000603811: Caudal Vertebra [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Andrej Čerňanský
Event date
March 20, 2022
Software
Avizo 8.1
Description
Caudal Vertebra
Description attachment
None
Media produced by this event on MorphoSource
Media 000603811: Caudal Vertebra [Mesh] [CT] (this media)