Media 000615417: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000615417: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000615417
Media type
Volumetric Image Series
Object element or part
Whole Body
Object represented
Object taxonomy
Citharichthys sordidus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
T. R. Clardy
Date created
February 09, 2024
Date uploaded
March 26, 2024
FILE OBJECT DETAILS Field Definitions
File name
LACM174_Rec.zip
File format(s)
ZIP archive, BMP
File size
78.1 MB
Image width
3072
Image height
1944
Color space
--
Color depth
8
Compression
None; BI_RGB; 0
X pixel spacing
52.000000
Y pixel spacing
52.000000
Z pixel spacing
52.000000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
1,852
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, LACM Ichthyology (Natural History Museums of Los Angeles County)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
LACM:Fish:174
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
LACM Ichthyology (Natural History Museums of Los Angeles County)
Creator
T. R. Clardy
Event date
February 09, 2024
Software
--
Description
Whole Body
Description attachment
None
Reference attachment
None
Exposure time
450
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
0
Projections
--
Voltage
70
Power
--
Amperage
214
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 3 activities
to create
derived
Media 000615417: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
T. R. Clardy
Event date
February 09, 2024
Software
NRecon
Description
--
Description attachment
None
Processing Activity 1: Align Parts
Software
NRecon
Description
Processing Activity 2: Crop
Software
NRecon
Description
Processing Activity 3: Reconstruction
Software
NRecon
Description
Media produced by this event on MorphoSource
Media 000615417: Whole Body [CTImageSeries] [CT] (this media)