Media 000615424: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000615424
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Xenocharax spilurus
Side
--
Orientation
--
Short description
HRXCT scan - whole body
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0873 Humphries: Xenocharax: Scans of the whole body of Xenocharax spilurus (CU 88746; Africa, Republic of Congo, Cuvette-Ouest, Lékoli River, Odzala National Park; 00°37'16"N 014°55'05"E; JPF 02-009; collected by JP Friel, S Lavoué 10 August 2002) for Dr. Julian Humphries of the University of Texas at Austin and Dr. Timothy Rowe of the Department of Geological Sciences, The University of Texas at Austin. Specimen scanned by Matthew Colbert 24 June 2003. This specimen was scanned from bottom to top, and the images were flipped. 16bitrot: 1024x1024 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, air wedge, no offset, slice thickness 2 lines (= 0.134 mm), S.O.D. 193 mm, 1600 views, 2 samples per view, inter-slice spacing 2 lines (= 0.134 mm), field of reconstruction 63 mm (maximum field of view 63.18497 mm), reconstruction offset 3400, reconstruction scale 1280. Flash-removal processing done by Rachel Racicot based on correction of raw sinogram data using IDL routines “RK_SinoRingProcSimul”, with default parameters. Rotation correction processing done by Rachel Racicot using IDL routine “DoRotationCorrection”. Total slices = 960.
Creator
Matthew Colbert
Date created
June 24, 2003
Date uploaded
March 26, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
710 MB
Image width
490
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.062000
Y pixel spacing
0.062000
Z pixel spacing
0.134000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
960

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Cornell University
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, IIS-0208675
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant IIS-0208675 to Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cumv:fish:88746 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
June 24, 2003
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000615424: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000615424: Whole Body [CTImageSeries] [CT] (this media)