Media 000623660: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000623660: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000623660
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Podilymbus podiceps podiceps
Object organization
Side
--
Orientation
--
Short description
HRXCT scan- skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1525
Triche:
podil: Scans of the skull and mandible of Podilymbus podiceps (TMM M-7139; male; coll: Jim Corbin, December 1969; Rockport, Aransas Co., TX) for Nina Triche of The University of Texas at Austin Department of Geological Sciences. Specimen scanned by Matthew Colbert 3 November 2006.
16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.11 mA, intensity control on, no filter, air wedge, no offset, slice thickness 2 lines (= 0.05573 mm), S.O.D. 80 mm, 1200 views, 2 samples per view, inter-slice spacing 2 lines (= 0.05573 mm), field of reconstruction 26.4 mm (maximum field of view 26.48619 mm), reconstruction offset 5500, reconstruction scale 5400. Acquired with 19 slices per rotation and 15 slices per set. Flash-removal processing done by Alison Mote based on correction of raw sinogram data using IDL routine “RK_SinoDeSpike” with default parameters. Reconstructed with an angle of 5 degrees. First four duplicate slices of each rotation deleted. Rotation correction processing done by Alison Mote using IDL routine “DoRotationCorrection.” Total final slices = 1110.
Creator
Matthew Colbert
Date created
November 03, 2006
Date uploaded
April 23, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bitrot.zip
File format(s)
ZIP archive, TIFF
File size
1.23 GB
Image width
863
Image height
856
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.025780
Y pixel spacing
0.025780
Z pixel spacing
0.055730
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,110
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, IIS-0208675
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant IIS-0208675 to Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmm:m:7139
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
November 03, 2006
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000623660: Skull [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000623660: Skull [CTImageSeries] [CT] (this media)