Media 000623680: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000623680: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000623680
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Chauna chavaria
Object organization
Side
--
Orientation
--
Short description
HRXCT scan- skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0031
dufeau/screamer:
Chauna chavaria (Crested Screamer), from the University of Kansas Museum of Natural History, specimen no. 81969. Collected by R.M. Chandler at the Henry Doorly Zoo, Omaha, NE, early 1982. Scanned for David Dufeau of the University of Texas Department of Geological Sciences.
8bit and 16bit: Scanning done by Cambria Denison and Richard Ketcham on 2/25/98.
II, 180 kV, 0.133 mA, no filter, air wedge, no offset, slice thickness 0.295 mm, S.O.D. 65 mm, 1800 views, 2 samples per view, interslice spacing 0.25 mm, field of reconstruction 52 mm, recon. offset 360, recon. scale 130. Done in 2 passes using 3-slice mode.
Creator
Cambria Denison and Richard Ketcham
Date created
February 25, 1998
Date uploaded
April 23, 2024
FILE OBJECT DETAILS Field Definitions
File name
16BIT.zip
File format(s)
ZIP archive, TIFF
File size
75.7 MB
Image width
512
Image height
512
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.102000
Y pixel spacing
0.102000
Z pixel spacing
0.250000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
360
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas Natural History Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
KU:KUO:81969
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000623680: Skull [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000623680: Skull [CTImageSeries] [CT] (this media)