Media 000633083: Whole Body
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000633083
Media type
Mesh
Object element or part
whole body
Object represented
Object taxonomy
Bolitoglossa lincolni
Object organization
Side
--
Orientation
--
Short description
--
Full description
mesh from microCT volume, data inverted following CT scan Record created by batch submission.
Creator
--
Date created
--
Date uploaded
May 30, 2024

FILE OBJECT DETAILS Field Definitions

File name
UCM_HERP_25520_Bolitoglossa_lincolni_MESH.stl
File format(s)
STL
File size
439 MB
Points
1334446
Polygons
2670632
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
43.032, 112.617, 20.462
Centroid coordinates
28.996, 64.720, 14.868 (Vertex Mean)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm), Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Colorado Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN partner NSF DBI-1701714; oMeso PEN NSF DBI-2001474
Publisher
University of Colorado Museum of Natural History
Cite as
UCM (catalog number)
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCM:Herp:UCM:Herp:25520 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
Creator
Touslee, Claire
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1601
Voltage
80
Power
7.0e-06
Amperage
75
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000438896: Whole Body [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Touslee, Claire
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000438896: Whole Body [CTImageSeries] [CT] was processed to create derived Media 000633083: Whole Body [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Chandrashekar, Chirag
Event date
April 26, 2024
Software
--
Description
Reconstructed tomography to mesh, with smoothing and noise reduction
Description attachment
None

Media produced by this event on MorphoSource

Media 000633083: Whole Body [Mesh] [CT] (this media)