Media 000633111: Left Cochlea
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000633111
Media type
Volumetric Image Series
Object element or part
left cochlea
Object represented
Object taxonomy
Zarhachis flagellator
Side
--
Orientation
--
Short description
HRXCT scan -- left cochlea
Full description
University of Texas High-Resolution X-ray CT Facility Archive 2451 Geisler: zarha: Scans of the left cochlea of Zarhochis flagellator (USNM 10485) for Jonathan Geisler of the New York College of Osteopathic Medicine. Specimen scanned by Matthew Colbert 26 April 2011. 16bit: 1024x1024 16-bit TIFF images. II, 210 kV, 0.17 mA, intensity control off, high-power mode, no filter, air wedge, no offset, slice thickness 1 line ( = 0.01568 mm), S.O.D. 45 mm, 1400 views, 3 samples per view, inter-slice spacing 1 line ( = 0.01568 mm), field of reconstruction 13.8 mm (maximum field of view 14.96976 mm), reconstruction offset 5000, scanner scale 2000, reconstruction scale 1600. Acquired with 31 slices per rotation and 25 slices per set. Drift-, streak- and ring-removal processing done by Satomi Ishihama based on correction of raw sinogram data using IDL routines “RK_SinoDeDrift” with parameter “/hi50, /despike, driftlength=21, goodfile=440”(applied twice), “RK_SinoDeStreak” with default parameters, and “RK_SinoRingProcSimul” with parameter “binwidth=21, bestof5=11.” Reconstructed with beam hardening coefficients using IDL FindBHC [Y found= 0.52, 0.08, 0.09, 0.10, 0.11, 0.13, 0.15, 0.18, 0.23, 0.33, 0.50, 1.93 with parameters “Num Coefs=10, Downsample=None, ROI mode=one material, Mono Function, Fix Endpoints, Non-Decreasing Shape”] and 1402 views. Deleted last 6 duplicate slices from each rotation. Post-reconstruction ring correction applied by Satomi Ishihama using the parameters oversample = 3.0, binwidth =17, sectors = 60. Total final slices = 775.
Creator
Matthew Colbert
Date created
April 26, 2011
Date uploaded
May 30, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.08 GB
Image width
1024
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.013480
Y pixel spacing
0.013480
Z pixel spacing
0.015680
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
775

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, DEB-1025260
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant DEB-1025260 to Jonathan Geisler. Funding for data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:paleobiology:10485 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000633111: Left Cochlea [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000633111: Left Cochlea [CTImageSeries] [CT] (this media)