Media 000635925: Partial Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000635925
Media type
Volumetric Image Series
Object element or part
partial skull
Object represented
Object taxonomy
Aetosauria indet.
Side
--
Orientation
--
Short description
HRXCT scan -- partial skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 3014 Rowe: aetos: Scans of the partial skeleton of an aetosaur (TMM 31100-1336. WPA quarries, Howard County, TX, excavated 1939-1941; Late Triassic) for Timothy Rowe of The University of Texas at Austin. Specimen scanned by Matthew Colbert 20 May 2013. 16bit: 1024x1024 16-bit TIFF images. II, 200 kV, 0.26 mA, intensity control off, high-power mode, no filter, empty container wedge, no offset, slice thickness 1 line ( = 0.07666 mm), S.O.D. 220 mm, 1400 views, 3 samples per view, inter-slice spacing 1 line ( = 0.07666 mm), field of reconstruction 73 mm (maximum field of view 73.18551 mm), reconstruction offset 5000, reconstruction scale 1000. Acquired with 31 slices per rotation and 25 slices per set. Drift-, fillin-, and ring-removal processing done by Julia Holland based on correction of raw sinogram data using IDL routines “RK_SinoDeDrift” with default parameters, “RK_SinoFillin” with parameters “1, /top” (slices 1024-1054), and “RK_SinoRingProcSimul” with parameter “bestof5=11.” Reconstructed with beam-hardening coefficients using IDL Find BHC [Y found = 0.06, 0.30, 0.57, 0.91, 1.25, 1.75, 2.57 with parameters “Num Coef=7, Downsample=4x, ROI mode=Joint, No Mono Function, Fix endpoints, No Exp (non-decreasing) slope, No Destreak]. Deleted first 3 and last 3 duplicate slices from each rotation. Rotation correction processing done by Julia Holland using IDL routine “DoRotationCorrection.” Deleted first 3 and last 13 blank slices. Post-reconstruction ring correction applied by Jessie Maisano using parameters oversample=3, binwidth=21, sectors=60. Total final slices = 1209.
Creator
Matthew Colbert
Date created
May 20, 2013
Date uploaded
June 07, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.06 GB
Image width
1000
Image height
626
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.071290
Y pixel spacing
0.071290
Z pixel spacing
0.076660
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,209

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:mwsu:3110-1336 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000635925: Partial Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000635925: Partial Skull [CTImageSeries] [CT] (this media)