Media 000635939: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000635939: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000635939
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Bassariscus astutus
Object organization
Side
--
Orientation
--
Short description
HRXCT scan -- skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1834
Rowe:
bassa: Scans of a skull of Bassariscus astutus (TMM M-473; Camp Wood, Real Co., TX; E. L. Lundelius) for Heather Ahrens, Tim Rowe, and ATOL. Specimen scanned by Matthew Colbert 31 March 2008.
16bit: 1024x1024 16-bit TIFF images. II, 220 kV, 0.14 mA, intensity control on, high-power mode, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.09721 mm), S.O.D. 140 mm, 1400 views, 2 samples per view, inter-slice spacing 2 lines (= 0.09721 mm), field of reconstruction 45 mm (maximum field of view 46.48 mm), reconstruction offset 4600, reconstruction scale 4900. Acquired with 19 slices per rotation and 15 slices per set. Deleted first four duplicate slices of each rotation except very first. First two and last eleven blank slices deleted from entire dataset. Total final slices = 786.
Creator
Matthew Colbert
Date created
March 31, 2008
Date uploaded
June 07, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
952 MB
Image width
999
Image height
880
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.043950
Y pixel spacing
0.043950
Z pixel spacing
0.097210
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
786
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
txvp:m:473
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000635939: Skull [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None