Media 000638808: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000638808: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000638808
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Acanthemblemaria hancocki
Object organization
Side
--
Orientation
--
Short description
--
Full description
LACM 31579-14 Acanthemblemaria hancocki
Creator
M.Wilson
Date created
June 22, 2024
Date uploaded
June 22, 2024
FILE OBJECT DETAILS Field Definitions
File name
LACMfishes31579_4_Rec.zip
File format(s)
ZIP archive, PNG
File size
160 MB
Image width
716
Image height
716
Color space
--
Color depth
--
Compression
Deflate/Inflate; Deflate
X pixel spacing
0.030000
Y pixel spacing
0.030000
Z pixel spacing
0.030000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,724
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, LACM Ichthyology (Natural History Museums of Los Angeles County)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
LACM:Fish:31579.004
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
LACM Ichthyology (Natural History Museums of Los Angeles County)
Creator
M. Wilson
Event date
June 22, 2024
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
470ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
55kV
Power
--
Amperage
200uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000638808: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
M.Wilson
Event date
June 22, 2024
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000638808: Whole Body [CTImageSeries] [CT] (this media)