Media 000641513: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000641513: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000641513
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Hapalemur griseus griseus
Object organization
Side
--
Orientation
--
Short description
HRXCT scan of head
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1368
Kirk:
Hapalemur: Scans of a thawed head of Hapalemur gresius gresius (DPC 1311; male, ‘Bedeveled’) for Chris Kirk of The University of Texas at Austin Anthropology Dept. and Richard Kay of Duke University. Specimen scanned by Matthew Colbert 14 December 2005. Scanned in two parts due to scanner breakdown; part “b” (900 slices) appended to original scan (450 slices).
16bitrot: 1024x1024 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, no offset, empty container wedge, slice thickness 1 line (= 0.05626 mm), S.O.D. 165 mm, 1600 views, 2 samples per view, inter-slice spacing 1 line (= 0.05626 mm), field of reconstruction 54 mm (maximum field of view 54.06124 mm), reconstruction offset 3680, scanner scale 3970, reconstruction scale 1200. Acquired with 25 slices per rotation. Drift and ring removal processing done by Alison Mote based on correction of raw sinogram data using IDL routines “RK_SinoDeDrift” with parameters “driftlength=21, goodfile=125” (from hepa scan), and “RK_SinoRingProcSimul” with default parameters. Reconstructed with an angle of 5 degrees. Rotation correction processing done by Alison Mote using IDL routine “DoRotationCorrection.” Deleted slices 1-25 in scan “b,” as they were duplicates and 1256-1325 of combined set were deleted, as they were extras. Total final slices = 1255.
Creator
Matthew Colbert
Date created
December 14, 2005
Date uploaded
July 01, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bitrot.zip
File format(s)
ZIP archive, TIFF
File size
1.58 GB
Image width
902
Image height
986
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.052730
Y pixel spacing
0.052730
Z pixel spacing
0.056260
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,255
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Chris Kirk. oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
cgm:c:1311
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
December 14, 2005
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000641513: Head [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000641513: Head [CTImageSeries] [CT] (this media)