Media 000642332: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

TAGS

GENERAL DETAILS Field Definitions

Media ID
000642332
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Glossophaga mutica
Side
NotApplicable
Orientation
--
Short description
Glossophaga mutica skull
Full description
MAM number 10639; female; original catalog number Osteo 9872 (MAM.O.09872); accn=VZA.00160
Creator
Laurel Yohe
Date created
April 21, 2024
Date uploaded
July 03, 2024

FILE OBJECT DETAILS Field Definitions

File name
YPM_MAM_10639_Glossophaga_mutica.zip
File format(s)
ZIP archive, PLY
File size
1.65 GB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.019744
Y pixel spacing
0.019744
Z pixel spacing
0.019744
Pixel spacing units
Mm
Slice thickness
0.1
Number of images in set
1

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon XT H 225 ST 2X, Yale Chemical and Biophysical Instrumentation Center (CBIC) (Yale University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ypm:vz:010639 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Yale Chemical and Biophysical Instrumentation Center (CBIC) (Yale University)
Creator
Laurel Yohe
Event date
April 21, 2024
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
3141
Voltage
177
Power
--
Amperage
102
Surrounding material
Green foam, Tape
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.0197442
Detector pixels Y
2000
Detector pixels size Y
0.0197442
Detector configuration
--
Source object distance
109.7913
Source detector distance
1112.138
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

Media produced by this event on MorphoSource

Media 000642332: Skull [CTImageSeries] [CT] (this media)