Media 000655212: FMNH UR 342 Araeoscelis femur
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

GENERAL DETAILS Field Definitions

Media ID
000655212
Media type
Volumetric Image Series
Object element or part
partial femur, distal
Object represented
Object taxonomy
Araeoscelis sp.
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Phoebe Fu
Date created
August 01, 2024
Date uploaded
August 07, 2024

FILE OBJECT DETAILS Field Definitions

File name
FMNH_UR_342_Araeoscelis_distal_femur_8bit.zip
File format(s)
ZIP archive, TIFF
File size
163 MB
Image width
497
Image height
434
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.019120
Y pixel spacing
0.019120
Z pixel spacing
0.019120
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,668

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:UR 342 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Roger Benson
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1601
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1668
Voltage
220
Power
--
Amperage
--
Surrounding material
foam
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000655212: FMNH UR 342 Araeoscelis femur (this media).

Processing Details Field Definitions

Creator
Phoebe Fu
Event date
August 01, 2024
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000655212: FMNH UR 342 Araeoscelis femur (this media)