Media 000656039: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000656039: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000656039
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Tomicodon boehlkei
Object organization
Side
--
Orientation
--
Short description
--
Full description
LACM 1083 Gobiesocidae Tomicodon boehlkei
Creator
M.Wilson
Date created
July 22, 2024
Date uploaded
August 13, 2024
FILE OBJECT DETAILS Field Definitions
File name
LACMfishes1083_Rec.zip
File format(s)
ZIP archive, PNG
File size
2.5 GB
Image width
2164
Image height
2164
Color space
--
Color depth
--
Compression
Deflate; Deflate/Inflate
X pixel spacing
0.019000
Y pixel spacing
0.019000
Z pixel spacing
0.019000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,836
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, LACM Ichthyology (Natural History Museums of Los Angeles County)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-2001443 (“CryptoVert”)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
LACM:Fish:1083.000
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
LACM Ichthyology (Natural History Museums of Los Angeles County)
Creator
M. Wilson
Event date
July 22, 2024
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
400ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
60kV
Power
--
Amperage
200uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000656039: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
M.Wilson
Event date
July 22, 2024
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000656039: Whole Body [CTImageSeries] [CT] (this media)