Media 000657200: Pes
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000657200
Media type
Mesh
Object element or part
Pes
Object represented
Object taxonomy
Dimetrodon milleri
Object organization
Side
Left
Orientation
--
Short description
Left pes of holotype
Full description
--
Creator
Peter Bishop
Date created
February 23, 2022
Date uploaded
August 19, 2024

FILE OBJECT DETAILS Field Definitions

File name
MCZ_VPRA-1365_Dimetrodon_milleri_Left_Pes_3D.stl
File format(s)
STL
File size
26.6 MB
Points
279078
Polygons
558040
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
52.217, 62.634, 116.680
Centroid coordinates
22.438, 27.561, 54.794 (Vertex Mean)
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Bishop, P.J. and Pierce, S.E. 2024. Late acquisition of erect hindlimb posture and function in the forerunners of therian mammals. Science Advances 10: adr2722.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:VP:VPRA-1365 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Peter Bishop
Event date
February 23, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
2.0 mm Cu
Exposure time
3400
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
320
Voltage
130 kV
Power
--
Amperage
278 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000657200: Pes [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Peter Bishop
Event date
February 23, 2022
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000657200: Pes [Mesh] [CT] (this media)