Media 000657212: Tibia
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000657212: Tibia
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000657212
Media type
Mesh
Object element or part
Tibia
Object represented
Object taxonomy
Eozostrodon parvus
Object organization
Side
Right
Orientation
--
Short description
Right proximal tibia
Full description
--
Creator
Peter Bishop
Date created
January 16, 2023
Date uploaded
August 19, 2024
FILE OBJECT DETAILS Field Definitions
File name
MCZ_VPM-19956_Eozostrodon_parvus_tibia_3D.stl
File format(s)
STL
File size
2.12 MB
Points
22099
Polygons
44378
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.955, 3.548, 2.660
Centroid coordinates
3.935, 3.187, 5.544 (Vertex Mean)
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, Museum of Comparative Zoology Scanning Facility (Harvard University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Bishop, P.J. and Pierce, S.E. 2024. Late acquisition of erect hindlimb posture and function in the forerunners of therian mammals. Science Advances 10: adr2722.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:VP:VPM-19956
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Peter Bishop
Event date
January 16, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
1.0 mm Al
Exposure time
288
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
90 kV
Power
--
Amperage
300 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000657212: Tibia [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Peter Bishop
Event date
January 16, 2023
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000657212: Tibia [Mesh] [CT] (this media)