Media 000665246: Mustela Sibirica Mandible
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000665246
Media type
Mesh
Object element or part
mandible
Object represented
Object taxonomy
Mustela sibirica
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
September 20, 2024

FILE OBJECT DETAILS Field Definitions

File name
Mustela_sibirica_F_USNM298999_mand.stl
File format(s)
STL
File size
151 MB
Points
1583688
Polygons
3167484
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
24.918, 28.262, 13.804
Centroid coordinates
14.629, 30.451, 20.558 (Vertex Mean)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:mammals:298999 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
Scan parameters: NSI scanner. Comet Microfocal source, 120 kV, 0.16 mA, aluminum foil filter, Perkin Elmer detector, 0.25 pF gain, 2 fps, 1x1 binning, source to object 201.172 mm, source to detector 1041.697 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 5 gain calibrations, 5 mm calibration phantom, data range [-2, 75] adjusted grayscale values, beam-hardening correction = 0.25. Voxel size = 38.6 μm. Total slices = 777.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000665246: Mustela Sibirica Mandible (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
Slicer
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000665246: Mustela Sibirica Mandible (this media)