Media 000670843: Endocast
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000670843
Media type
Mesh
Object element or part
Endocast
Object represented
Object taxonomy
Pardalotus punctatus
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Aubrey Keirnan
Date created
October 12, 2024
Date uploaded
October 12, 2024

FILE OBJECT DETAILS Field Definitions

File name
Pardalotus_punctatus_122940.stl
File format(s)
STL
File size
42.1 MB
Points
83887
Polygons
167770
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
11.161, 10.291, 10.430
Centroid coordinates
20.306, 10.531, 71.281 (Vertex Mean)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VZ:YPM ORN 122940 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Matt Gage
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
1.085
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
5
Projections
1200
Voltage
50
Power
0.0075
Amperage
150
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000081968: Skeleton [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matt Gage
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000081968: Skeleton [CTImageSeries] [Etc] was processed to create derived Media 000670843: Endocast [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Aubrey Keirnan
Event date
--
Software
Geomagic
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000670843: Endocast [Mesh] [CT] (this media)