Media 000671105: Etheostoma Vitreum Dice Ct Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000671105: Etheostoma Vitreum Dice Ct Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000671105
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Etheostoma vitreum
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Jessica Arbour
Date created
December 10, 2020
Date uploaded
October 12, 2024
FILE OBJECT DETAILS Field Definitions
File name
stack.zip
File format(s)
ZIP archive, BMP
File size
251 MB
Image width
530
Image height
530
Color space
--
Color depth
24
Compression
BI_RGB; None; 0
Series type
Reconstructed image stack
X pixel spacing
17.200000
Y pixel spacing
17.200000
Z pixel spacing
17.200000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
1,158
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco uCT50, Center for Small Animal Imaging (Vanderbilt University Institute of Imaging Science)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UMMZ:ummz_fish:168944
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Center for Small Animal Imaging (Vanderbilt University Institute of Imaging Science)
Creator
J. Arbour
Event date
December 10, 2020
Software
Scanco
Description
diceCT scan of cranial musculature (1% Lugol's iodine)
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
55kV
Power
--
Amperage
200uA
Surrounding material
Plastic Film
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000671105: Etheostoma Vitreum Dice Ct Head (this media).
Processing Details Field Definitions
Creator
Jessica Arbour
Event date
--
Software
Scanco
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000671105: Etheostoma Vitreum Dice Ct Head (this media)