Media 000674816: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

Media preview disabled by data contributor.

In Collections

Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000674816
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Hypsugo savii
Side
--
Orientation
--
Short description
micro-CT data - tomograms, not reconstructed
Full description
Computed tomography voxel dataset for ummz:mammals:117578-Hypsugo SAVII CAUCASICUS-Skull; Full CT Image Series available at https://deepblue.lib.umich.edu/data/concern/data_sets/gt54kp05n Record created by batch submission.
Creator
Ramon Nagesan
Date created
--
Date uploaded
October 24, 2024

FILE OBJECT DETAILS Field Definitions

File origin
Remote
File name
9880vs029
File format(s)
TIFF
File size
7.63 MB
Image width
2000
Image height
2000
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Projections
X pixel spacing
1147.000000
Y pixel spacing
1066.000000
Z pixel spacing
719.000000
Pixel spacing units
Mm
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Thumbnail Only
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
doi:10.7302/57vk-vr83

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummz:mammals:117578 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
Creator
--
Event date
November 01, 2021
Software
Xtek 5.4
Description
--
Description attachment
None
Reference attachment
None
Filter
no
Exposure time
250
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1601
Voltage
100
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
tungsten
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000674816: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource