Media 000680868: Plastron
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000680868
Media type
Mesh
Object element or part
Plastron
Object represented
Object taxonomy
Geochelone elegans
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Guilherme Hermanson
Date created
November 19, 2024
Date uploaded
November 19, 2024

FILE OBJECT DETAILS Field Definitions

File name
Geochelone_elegans_MVZ-herp-233519_Plastron.ply
File format(s)
PLY
File size
54.4 MB
Points
1293814
Polygons
2591904
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
109.806, 178.731, 100.577
Centroid coordinates
81.492, 117.059, 58.248 (Bounding Box)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
SNSF Ambizione PZ00P2_202019/1
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MVZ:Herp:MVZ:Herp:233519 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zach Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1560
Voltage
120
Power
0.0288
Amperage
240
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000423812: Whole Body [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Zach Randall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000423812: Whole Body [CTImageSeries] [CT] was processed to create derived Media 000680868: Plastron [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Guilherme Hermanson
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000680868: Plastron [Mesh] [CT] (this media)