Media 000681320: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000681320
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Amphichthys cryptocentrus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Diego B. Vaz
Date created
March 07, 2017
Date uploaded
November 22, 2024

FILE OBJECT DETAILS Field Definitions

File name
MCZ_34685_Amphichthys_cryptocentrus_3d_Recon.zip
File format(s)
ZIP archive, BMP
File size
536 MB
Image width
796
Image height
736
Color space
--
Color depth
8
Compression
0; None; BI_RGB
Series type
Reconstructed image stack
X pixel spacing
29.037682
Y pixel spacing
29.037682
Z pixel spacing
29.037682
Pixel spacing units
Um
Slice thickness
--
Number of images in set
2,203

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Ich:34685 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Diego Vaz
Event date
March 07, 2017
Software
SkyScan
Description
full body scan
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
850
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
959
Voltage
60
Power
--
Amperage
133
Surrounding material
cheesecloth
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
213
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000681320: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Diego Vaz
Event date
March 07, 2017
Software
NRecon
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
nrecon
Description

Media produced by this event on MorphoSource

Media 000681320: Whole Body [CTImageSeries] [CT] (this media)