Media 000453798: Internal Ear
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000453798: Internal Ear
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000453798
Media type
Volumetric Image Series
Object element or part
internal ear
Object represented
Object taxonomy
Heterocephalus glaber
Object organization
Side
--
Orientation
--
Short description
internal ear of the mole rats specimens
Full description
--
Creator
--
Date created
January 13, 2019
Date uploaded
August 02, 2022
FILE OBJECT DETAILS Field Definitions
File name
CT_images.zip
File format(s)
ZIP archive, TIFF
File size
4.38 GB
Image width
1000
Image height
666
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
3.000000
Y pixel spacing
3.000000
Z pixel spacing
3.000000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
21,368
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1172, Bruker MicroCT (Bruker MicroCT)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
Jana Goyens
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
pdn:pe-pi
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Bruker MicroCT (Bruker MicroCT)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
3450 ms
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
6
Projections
--
Voltage
60 KV
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
0,11
Phase contrast
Yes
Optical magnification
Yes
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 3 activities
to create
derived
Media 000453798: Internal Ear [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
January 13, 2019
Software
NReco software
Description
--
Description attachment
None
Processing Activity 1: Smoothing/Noise Reduction
Software
NReco Software
Description
Processing Activity 2: Reconstruction
Software
NReco Software
Description
Processing Activity 3: Crop
Software
IrfanView 64 Software
Description
Media produced by this event on MorphoSource
Media 000453798: Internal Ear [CTImageSeries] [CT] (this media)