GENERAL DETAILS Field Definitions
Media ID
000040580
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Eupolybothrus liburnicus
Object organization
Side
NotApplicable
Orientation
--
Short description
CHP545_IKI_prefemur_2-7um_8bTIFF
Full description
Migrated MorphoSource 1 Media File Title: CHP545_IKI_prefemur_2-7um_8bTIFF Migrated MorphoSource 1 Media Group Title: MicroCT image data for holotype CHP545 Migrated MorphoSource 1 Media File Description: Higher magnification microCT images of holotype CHP545 prefemur region, 8-bit TIFF, 2.7um voxels, IKI contrast
Creator
--
Date created
--
Date uploaded
February 09, 2018
FILE OBJECT DETAILS Field Definitions
File name
CPH545_IKI_prefemur_2-7um_8bTIFF.zip
File format(s)
ZIP archive, TIFF
File size
3.5 GB
Image width
1984
Image height
2946
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
--
Y pixel spacing
--
Z pixel spacing
--
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,424
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT, Department of Theoretical Biology (University of Vienna)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
N. Akkari, A. Ganske, B. Metscher, Ana Komerički
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
cbss:chp:545
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Department of Theoretical Biology (University of Vienna)
Creator
Dr. Brian Metscher
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000040580: Element Unspecified [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Dr. Brian Metscher
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource