Media 000678713: Canalis Cavernosus
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000678713
Media type
Mesh
Object element or part
Canalis cavernosus
Object represented
Object taxonomy
Azabbaremys moragjonesi
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
November 07, 2024
Date uploaded
November 07, 2024

FILE OBJECT DETAILS Field Definitions

File name
2_CCv_L.stl
File format(s)
STL
File size
24.7 MB
Points
264956
Polygons
518003
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
473.599, 280.908, 421.172
Centroid coordinates
1496.285, 841.242, 769.985 (Vertex Mean)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
The Trustees of the Natural History Museum, London
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NHMUK:PAL:PV R 16370 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3600
Voltage
200
Power
--
Amperage
150
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000677617: Skull [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
Raw media obtained from NMHUK scanner was processed to create derivated tiff media data
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000677617: Skull [CTImageSeries] [CT] was processed to create derived Media 000678713: Canalis Cavernosus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000678713: Canalis Cavernosus [Mesh] [CT] (this media)