Media 000390229: Element Unspecified
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000390229
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Nanosaurus sp.
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Keegan Melstrom
Date created
January 12, 2021
Date uploaded
October 08, 2021

FILE OBJECT DETAILS Field Definitions

File name
MWC_5822_Nanosaurus_MorphoSource.ply
File format(s)
PLY
File size
18.8 MB
Points
307261
Polygons
613204
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
395.658, 207.220, 1454.429
Centroid coordinates
305.575, 486.808, 1214.683
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m, Molecular Imaging Center (University of Southern California)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mwc:5822 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Molecular Imaging Center (University of Southern California)
Creator
Tautis Skorka
Event date
September 30, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000390229: Element Unspecified [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Keegan Melstrom
Event date
January 12, 2021
Software
Avizo
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000390229: Element Unspecified [Mesh] [CT] (this media)