Media 000164641: Element Unspecified
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000164641: Element Unspecified
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000164641
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Milvus migrans
Object organization
Side
--
Orientation
--
Short description
STL_SKULL_Mmigra_28278
Full description
Migrated MorphoSource 1 Media File Title: STL_SKULL_Mmigra_28278 Migrated MorphoSource 1 Media Group Title: Mmigra skull 28278
Creator
--
Date created
--
Date uploaded
October 09, 2020
FILE OBJECT DETAILS Field Definitions
File name
Mmigra_Skull_28278.stl
File format(s)
STL
File size
685 MB
Points
7154793
Polygons
14364730
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
38.139, 35.783, 69.225
Centroid coordinates
5.969, -3.825, -15.335
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Inveon Multimodal Platform, The Centre for Advanced Imaging (National Imaging Facility) (University of Queensland)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
qm:o:28278
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The Centre for Advanced Imaging (National Imaging Facility) (University of Queensland)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000100594: Element Unspecified [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000100594: Element Unspecified [CTImageSeries] [CT]
was processed
to create
derived
Media 000164641: Element Unspecified [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000164641: Element Unspecified [Mesh] [CT] (this media)