Media 000427847: Whole
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000427847: Whole
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000427847
Media type
Volumetric Image Series
Object element or part
Whole
Object represented
Object taxonomy
Diodon nicthemerus
Object organization
Side
--
Orientation
--
Short description
Diodon nicthemerus
Full description
--
Creator
Christopher Goatley
Date created
March 04, 2022
Date uploaded
March 04, 2022
FILE OBJECT DETAILS Field Definitions
File name
AMS_I_20189-009_Diodon_nicthemerus_TIFF.zip
File format(s)
ZIP archive, TIFF
File size
5.96 GB
Image width
1999
Image height
1999
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.067081
Y pixel spacing
0.067081
Z pixel spacing
0.067081
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,000
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, School of Environmental and Rural Science (University of New England)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
am:ichthyology:20189-009
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
School of Environmental and Rural Science (University of New England)
Creator
Christopher Goatley
Event date
--
Software
GE
Description
--
Description attachment
None
Reference attachment
None
Exposure time
800ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1800
Voltage
190kV
Power
--
Amperage
100uA
Surrounding material
Chux reusable wipe
X-ray tube type
micro-focus 240, reflection
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000427847: Whole [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Christopher Goatley
Event date
--
Software
GE
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000427847: Whole [CTImageSeries] [CT] (this media)