Media 000428573: Whole
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000428573
Media type
Volumetric Image Series
Object element or part
Whole
Object represented
Object taxonomy
Anoplocapros inermis
Side
--
Orientation
--
Short description
Anoplocapros inermis
Full description
--
Creator
Christopher Goatley
Date created
March 07, 2022
Date uploaded
March 07, 2022

FILE OBJECT DETAILS Field Definitions

File name
AMS_I_36894-001_Anoplocapros_inermis_TIFF.zip
File format(s)
ZIP archive, TIFF
File size
5.53 GB
Image width
1999
Image height
1999
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.059255
Y pixel spacing
0.059255
Z pixel spacing
0.059255
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,000

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, School of Environmental and Rural Science (University of New England)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object am:ichthyology:36894-001 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
School of Environmental and Rural Science (University of New England)
Creator
Christopher Goatley
Event date
--
Software
GE
Description
--
Description attachment
None
Reference attachment
None
Exposure time
800ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1800
Voltage
180kV
Power
--
Amperage
100uA
Surrounding material
Chux reusable wipe
X-ray tube type
micro-focus 240, reflection
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000428573: Whole [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Christopher Goatley
Event date
--
Software
GE
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000428573: Whole [CTImageSeries] [CT] (this media)