Media 000063187: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000063187
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Micrurus ancoralis
Object organization
Side
--
Orientation
--
Short description
CT of pathogenic Vertebrae - R-55945
Full description
Migrated MorphoSource 1 Media File Title: CT of pathogenic Vertebrae - R-55945 Migrated MorphoSource 1 Media Group Title: Vertebrae of R-55945 - pathogenic
Creator
--
Date created
--
Date uploaded
November 01, 2018

FILE OBJECT DETAILS Field Definitions

File name
R-55945_cancer_09January2018_cb_crop_rotate.zip
File format(s)
ZIP archive, TIFF
File size
539 MB
Image width
816
Image height
616
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.009000
Y pixel spacing
0.009000
Z pixel spacing
0.009000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
876

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Shimadzu SMX-100CT, Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Alexander S. Hall provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uta:uta-r:55945 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)
Creator
Justin L. Jacobs
Event date
--
Software
--
Description
40kv_40ua_polyAcetal
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
6
Projections
1200
Voltage
40
Power
--
Amperage
40
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000063187: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Justin L. Jacobs
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000063187: Element Unspecified [CTImageSeries] [Etc] (this media)