Media 000063212: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000063212
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Micrurus ancoralis
Object organization
Side
--
Orientation
--
Short description
Label Data for non-pathogenic Vertebrae - R-55945
Full description
Migrated MorphoSource 1 Media File Title: Label Data for non-pathogenic Vertebrae - R-55945 Migrated MorphoSource 1 Media Group Title: Vertebrae of R-55945 - non-pathogenic Migrated MorphoSource 1 Media File Description: Label Data for non-pathogenic Vertebrae - R-55945
Creator
--
Date created
--
Date uploaded
November 01, 2018

FILE OBJECT DETAILS Field Definitions

File name
R-55945_non-pathogenic_labels.zip
File format(s)
ZIP archive, TIFF
File size
5.24 MB
Image width
751
Image height
557
Color space
RGB Palette
Color depth
8
Compression
LZW
X pixel spacing
0.011000
Y pixel spacing
0.011000
Z pixel spacing
0.011000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
877

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Shimadzu SMX-100CT, Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Alexander S. Hall provided access to these dataoriginally appearing in , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uta:uta-r:55945 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)
Creator
Justin L. Jacobs
Event date
--
Software
--
Description
35kv_40ua_polyacetal
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
6
Projections
1200
Voltage
35
Power
--
Amperage
40
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000063185: Element Unspecified [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Justin L. Jacobs
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000063185: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000063212: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Justin L. Jacobs
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000063212: Element Unspecified [CTImageSeries] [Etc] (this media)